Motorised Automatic Transfer Switch (ATS) — contactors & switching spare part for diesel generators
Contactors & Switching

Motorised Automatic Transfer Switch (ATS)

Order In (3–5 days)

Motor-operated automatic transfer switch for changing over between mains and generator. Mechanically and electrically interlocked so both sources can never be connected at once.

Compatible With

Schneider ElectricChintLovatoUniversal fit

Pricing

Prices vary with market supply. Contact us for a current quote tailored to your order size.

1
Request Quote via WhatsAppQuote to supply & fit
Nationwide Delivery
6-Month Warranty
Expert Support

Specifications

Current range63 A to 3200 A
Poles3P or 4P
Operating voltage400 V AC (three-phase)
InterlockingMechanical and electrical
ControlFrom the generator's AMF controller or built-in controller
StandardIEC 60947-6-1

What the Motorised Automatic Transfer Switch (ATS) does

An automatic transfer switch moves your building's supply from mains to generator when the power fails, and back again when it returns — without anyone flipping a switch. Motor-operated ATS units are mechanically and electrically interlocked, so both sources can never be connected at once.

Paired with an AMF controller such as the DSE7320 MKII, an ATS turns a manual standby generator into a fully automatic backup system — essential for hospitals, data rooms, hotels and offices.

Signs it needs replacing

  • Someone has to switch over by hand during every outage.
  • Existing changeover failing to transfer or sticking.
  • Contactor changeover overheating at high current.

Get the right part first time

Send us these on WhatsApp and our engineers will confirm the exact part before you pay:

  • Main incomer current rating and number of poles.
  • Your generator controller model.
  • A photo of the generator nameplate (make, model, kVA, serial number).
Send photos on WhatsApp

Fitting notes

An ATS is installed at the main incomer and must be sized for the full load, wired with correct cable sizes and protection, and commissioned with a real mains-failure test. This is a job for qualified electricians and generator engineers — we design, install and commission it.

Frequently asked questions

ATS or contactor changeover — which is better?+

Both work. Motorised ATS units are compact and suit higher currents; contactor panels are economical at lower ratings. We recommend based on your load.

How long does changeover take?+

The generator first starts and stabilises — usually several seconds — then the ATS transfers. For zero-break power, critical loads need a UPS as well.

Do you install and commission it?+

Yes, including a live mains-failure test and handover.

Often needed with this part

Order online — same-day dispatch in Nairobi, nationwide delivery in 1–3 days.

Browse all parts

Not sure which part you need? WhatsApp our engineers — free technical advice.