PPK-CON-EM001

Contactors & Switching

Electromagnetic Contactor (Schneider / Chint / ABB)

In Stock

Heavy-duty contactors for generator changeover, motor starting and load control — Schneider LC1, Chint NC1 and ABB AF series. Specify brand, current and coil voltage when ordering.

Compatible With

Schneider ElectricChintABB

Pricing

Prices vary with market supply. Contact us for a current quote tailored to your order size.

1
Request Quote via WhatsAppQuote to supply & fit
Nationwide Delivery
6-Month Warranty
Expert Support

Specifications

BrandsSchneider, Chint, ABB
Current range9 A to 800 A
Poles3P or 4P
Coil voltage24 V DC or 230 V AC
InstallationIP20 — must be mounted in an enclosure

What the Electromagnetic Contactor (Schneider / Chint / ABB) does

Contactors switch heavy loads by remote control. In generator systems they make the changeover between mains and generator, start large motors and shed non-essential loads.

A contactor's main contacts wear each time they switch under load. Pitted, burnt or welded contacts cause overheating, voltage drop and, in a changeover, the risk of failing to transfer.

Signs it needs replacing

  • Burnt, pitted or welded main contacts.
  • Contactor overheating or discoloured.
  • Failure to close or open; mechanical sticking.

Get the right part first time

Send us these on WhatsApp and our engineers will confirm the exact part before you pay:

  • Brand, model and current rating from the existing contactor.
  • Coil voltage and number of poles.
  • Load current it switches.
Send photos on WhatsApp

Fitting notes

Isolate and prove both sources dead. Size the contactor for the load current and type of load — motor loads need a higher rating. In changeovers, mechanical and electrical interlocking must be retained so mains and generator can never connect together.

Frequently asked questions

What size contactor do I need?+

It depends on the load current and the type of load. Send us the existing contactor details or the load and we will size it.

Are 3-pole or 4-pole contactors used for changeover?+

It depends on the earthing arrangement and whether the neutral must be switched. Our engineers advise based on your installation.

Why is the interlock important?+

It prevents mains and generator being connected together, which can destroy the generator and endanger workers on the grid.

Often needed with this part

Order online — same-day dispatch in Nairobi, nationwide delivery in 1–3 days.

Browse all parts

Not sure which part you need? WhatsApp our engineers — free technical advice.